Methods
Products
The products section of a report: each product counted through its components and their materials, kits through the products they contain, reusable instruments per use, and what was opened but not used.
Methods of ClinImpact 2.21. Reports name the version they were computed with; the changelog says what changed.
Contents
Products#
A product is its components and their materials. Each material counts as quantity × unit conversion × the counts down the component tree × units consumed over the recorded procedures × the BAFU factor. A material without a factor under the chosen indicator is shown and not counted.
Kits and packs#
A product can contain other products, as a kit or pack does (a syringe, a needle and a drape in an anaesthesia set). Such a component is that product and a number of units of it, with no materials or disposal of its own. The contained product's components, materials and disposals are read as they stand, so a change to that product carries through to every kit that contains it.
A kit counts as the sum of its own components and of each contained product × its count, compounded down the tree like any other count, in its mass, production, end of life and recycling credit.
- On a project its lines stay under the kit, and their labels run through the contained product's name.
- Transport follows the way a kit is made. Each contained product travels from its own origin to the kit's origin, where the kit is assembled (a kit inside a kit, leg by leg); the kit then travels as one unit, with the mass of all its parts, to the hospital. A contained product, or a kit, without a country is named on a line of its own and not counted on that leg.
- Its price is the kit's own.
A product cannot contain itself, directly or through another product. A medication cannot be part of a product either: its drug is counted on the project from the dose and container recorded there.
Reusable instruments#
A product can be marked a reusable instrument, with its number of uses over its life. This is 400 unless recorded otherwise (Rizan et al., Int J Life Cycle Assess 2022, surgical scissors with repairs), and the source of the number is kept beside it.
Per use, its production (its material lines), its end of life and recycling credit, and its mass in transport count once divided by its uses, and the trace says so ("÷ 400 uses (reusable)"). Its washing and sterilising are not in that figure; they are counted through the DIN baskets, under Sterilisation.
Within kits, every component counts per use of the innermost reusable product on its path:
- A reusable product divides its whole tree.
- A reusable product inside a single-use kit divides only its own part.
- Inside a reusable kit, a reusable part counts by its own uses alone, not by the kit's as well.
A product's own page keeps its figures per unit. A drug cannot be reusable.
Opened, not used#
A product line can record how many of its units were opened but not used. They stay in the result, since an opened unit is made, shipped and thrown away whether it was used or not. The report gives their share separately, as the product's frozen figure × units not used ÷ units opened, so a study can state how much of its footprint was opened in vain.